DRAFT, needs technical review. Not for publication. The title is our own wording, not the official Paris MoU text.

PSC deficiency code 01117: International Oil Pollution Prevention Certificate validity

Category Statutory certificates (MARPOL Annex I)
Related certificate International Oil Pollution Prevention (IOPP)
Main references MARPOL Annex I Regs 6, 7 and 10 (surveys, certification, validity)
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • IOPP expired or survey overdue
  • Form B supplement not matching equipment
  • Equipment list differs from onboard layout
  • Survey endorsement missing after modification
  • Electronic IOPP on board not meeting FAL.5/Circ.39/Rev.2 guidelines where e-certificates are used

Typical root causes

  • Equipment change after survey not reported
  • Annual survey slippage
  • Confusion between class and flag endorsements
  • Digital certificate not downloaded to ship

Corrective action (example)

Complete survey; update Form B; align equipment with certificate; obtain endorsed IOPP.

Preventive action (example)

Trigger survey request when OWS or tanks modified; joint class-flag review.

Evidence to attach for close-out

  • IOPP and Form B
  • Survey report
  • Equipment photos
  • Class notification

Related

  • Codes: 14101, 14104, 01107
  • SIRE 2.0: Chapter 6 (pollution prevention) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page