PSC deficiency code 02108: General electrical installations and insulation condition

Category Structural / machinery (SOLAS II-1)
Related certificate Cargo Ship Safety Construction
Main references SOLAS II-1/45 and IEC standards as applicable
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Exposed conductors or broken conduit in machinery spaces
  • Earth fault indications not investigated
  • Overloading of panels with improvised connections
  • Explosion-proof fittings damaged on tankers
  • Incomplete insulation resistance records

Typical root causes

  • Temporary repairs left permanent
  • Vibration loosening terminations
  • Moisture ingress in decks and casings
  • Chief engineer workload deferring thermographic survey

Corrective action (example)

Make permanent repairs to wiring and enclosures; clear earth faults; restore IP rating of fittings; record insulation tests.

Preventive action (example)

Schedule periodic IR tests; require electrician sign-off on temporary repairs.

Evidence to attach for close-out

  • IR test sheet
  • Photos of corrected installation
  • Earth fault investigation report
  • Work permit close-out

Related

  • Codes: 13101, 04103, 02109
  • SIRE 2.0: Chapter 8 (electrical systems) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.