PSC deficiency code 05114: Reserve source of energy for radio installations

Category Radio communications (SOLAS IV)
Related certificate Cargo Ship Safety Radio
Main references SOLAS IV/13
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Batteries unable to supply GMDSS equipment for required period
  • Charger not maintaining capacity; terminals corroded
  • No label with installation date or capacity test
  • Switchover to reserve not demonstrated
  • Distress equipment not connected to reserve bus

Typical root causes

  • Battery age beyond replacement policy
  • High ambient temperature reducing life
  • Infrequent capacity tests
  • Radio maintenance contract scope unclear

Corrective action (example)

Replace or recharge battery bank; clean terminals; prove capacity test; document switchover procedure.

Preventive action (example)

Track battery installation date; align tests with radio survey schedule.

Evidence to attach for close-out

  • Capacity test record
  • Battery delivery note
  • GMDSS log entries
  • Photo of labelled bank

Related

  • Codes: 05101, 04103, 10111
  • SIRE 2.0: Chapter 7 (communications) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page