PSC deficiency code 10112: Electronic charts (ECDIS)

Deficiency code: Paris MoU on Port State Control, List of Deficiency Codes including Statutory Certificates (1 July 2026). Page titles are closethecap.com's own wording.

Free close-out tool

Close out this finding

Use our free generator for PSC deficiency code 10112 (Electronic charts (ECDIS)). Paste your finding text to draft root cause, corrective and preventive actions, and an evidence checklist — no login required.

closethecap.com guidance

Page titles, inspection look-fors, root causes, corrective and preventive actions, references and close-out tips are provided independently by closethecap.com. They are not Paris MoU content and are not endorsed by the Paris MoU.

Category Navigation (SOLAS V)
Related certificate Cargo Ship Safety Equipment
Main references SOLAS V/19.2.1.4, V/19.2.10, V/27; ECDIS performance standard MSC.232(82) as amended MSC.530(106)
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • ECDIS not using official ENCs for planned voyage
  • Back-up arrangement not ready or not tested
  • Safety settings incorrect or crew cannot explain XTE and safety contour
  • Licence or permit for ENC cells expired
  • Master's ECDIS familiarisation not documented

Typical root causes

  • Passage plan copied without updating cell permit
  • Training focused on paper chart fleet habits
  • Software update deferred causing compatibility issues
  • Assumption that raster charts satisfy ECDIS carriage

Corrective action (example)

Install required ENC permits; configure safety settings per company policy; test back-up; document familiarisation.

Preventive action (example)

Pre-voyage ECDIS audit in passage planning procedure; fleet ECDIS competency refresher.

Evidence to attach for close-out

  • ENC permit screenshot
  • Passage plan ECDIS layer export
  • Back-up test log
  • Training record

Related

  • Codes: 10111, 10116, 10113
  • SIRE 2.0: Chapter 2 (navigation) (chapter reference only)

Free close-out tool

Generate your close-out report

Use our free generator for PSC deficiency code 10112 (Electronic charts (ECDIS)). Paste your finding text to draft root cause, corrective and preventive actions, and an evidence checklist — no login required.