PSC deficiency code 03108: Ventilator coamings, air pipes and deck casings weathertightness

Category Watertight / weather integrity (Load Line)
Related certificate Load Line / Cargo Ship Safety Construction
Main references Load Line Convention Reg. 19–20
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Ventilator closing devices missing or cannot be secured
  • Corroded coamings allowing water ingress
  • Non-weathertight improvised covers
  • Air pipe flame screens missing or clogged
  • Casings with cracked welds or temporary patches

Typical root causes

  • Impact damage not reported
  • Rust scale not removed in maintenance
  • Wrong type of temporary cover used repeatedly
  • Cargo operations prioritised over closing devices

Corrective action (example)

Renew closing appliances; repair coamings; fit correct screens; pressure-test or hose-test as appropriate and record.

Preventive action (example)

Add ventilator and air pipe walk-down before heavy weather and PSC prep.

Evidence to attach for close-out

  • Photos before/after
  • Repair specification
  • Master's standing order acknowledgment
  • PMS entry

Related

  • Codes: 02101, 07116, 03105
  • SIRE 2.0: Chapter 8 (deck and hull) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page