PSC deficiency code 07116: Ventilation arrangements for machinery and cargo spaces
| Category | Fire safety (SOLAS II-2) |
| Related certificate | Cargo Ship Safety Equipment |
| Main references | SOLAS II-2/5.2.1, II-2/9.7; II-2/4.5.4 (cargo pump-room ventilation on tankers) |
| Typical action codes | 17 (rectify before departure), 30 (detainable) if serious |
| Commonly detainable? | Can be, depending on severity (no statistics claimed) |
What PSC officers look for
- Ventilation fans running when required stopped after shutdown
- Temporary covers left on intakes or exhausts
- Combustible deposits inside ducts
- Inadequate separation between exhaust and intake openings
- Missing flame screens on fuel tank vents where required
Typical root causes
- Operational habit of leaving fans running for comfort
- Cleaning of ducts not in PMS
- Structural modifications without re-checking ventilation balance
- Poor handover between crews on fan stop procedures
Corrective action (example)
Clean ducts as needed; restore screens and covers; demonstrate correct stop/start for fire scenarios; remove combustible storage from ventilation paths.
Preventive action (example)
Schedule duct inspection intervals; reinforce fan-stop steps in fire drill briefings.
Evidence to attach for close-out
- Cleaning records
- Photos of restored screens
- Drill checklist
- Risk assessment update if layout changed
Related
Generate a close-out report for this finding · Download the CAP template
Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.