DRAFT, needs technical review. Not for publication. The title is our own wording, not the official Paris MoU text.

PSC deficiency code 07105: Fire doors and openings in fire-resisting divisions

Category Fire safety (SOLAS II-2)
Related certificate Cargo Ship Safety Equipment / Safety Construction
Main references SOLAS II-2/9 and the FSS Code
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Self-closing fire doors that don't close fully or latch
  • Doors held open with wedges, hooks or ropes
  • Damaged seals, door closers or hold-back magnets
  • Unauthorised openings or penetrations in A- or B-class divisions
  • Release from the bridge or fire control station not working

Typical root causes

  • Closers worn or never adjusted; not in the PMS
  • Doors propped open for ventilation or convenience
  • Cable or pipe work by contractors without restoring the insulation
  • Rounds not checking that doors operate

Corrective action (example)

Repair or adjust each closer and latch; remove hold-open devices; restore the insulation of penetrations with approved materials; test all fire doors and record the results.

Preventive action (example)

Add weekly fire-door operational checks to the PMS; brief crew on why doors must stay closed; add 'fire doors' to the hot-work and contractor close-out checklist.

Evidence to attach for close-out

  • Before and after photos for each door
  • PMS job record with test results
  • Material certificates for penetration seals
  • Crew briefing record

Related

  • Codes: 07101, 07115, 07123
  • SIRE 2.0: Chapter 5 (safety management, fire safety) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page