PSC deficiency code 07106: Fire detection and alarm system
| Category | Fire safety (SOLAS II-2) |
| Related certificate | Cargo Ship Safety Equipment |
| Main references | SOLAS II-2/7 and FSS Code ch. 9 |
| Typical action codes | 17 (rectify before departure), 30 (detainable) if serious |
| Commonly detainable? | Can be, depending on severity (no statistics claimed) |
What PSC officers look for
- Detectors faulty, disabled or isolated without a record
- Panel shows faults or disconnected loops
- Alarms not audible in all required spaces
- No test records, or tests not covering all detectors
Typical root causes
- Detectors isolated during hot work and not reinstated
- Ageing heads and no spare parts
- Testing done by sampling only, without rotating coverage
Corrective action (example)
Repair or replace faulty detectors; clear panel faults; reinstate isolated zones; test the whole system and record the results.
Preventive action (example)
Add an isolation log with sign-off for reinstatement; plan rotating detector tests so each head is covered within the PMS cycle; check spares stock.
Evidence to attach for close-out
- Panel printout or photo with no faults
- Detector test log
- Isolation log page
- Service report from the maker or an approved firm, if used
Related
Generate a close-out report for this finding · Download the CAP template
Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.