PSC deficiency code 07109: Fixed fire-extinguishing installation

Category Fire safety (SOLAS II-2)
Related certificate Cargo Ship Safety Equipment
Main references SOLAS II-2/10 and FSS Code ch. 5–7
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • CO2 or other system not serviced within the required interval
  • Release controls, alarms or time delay not working
  • Cylinders low or leaking; wrong number of cylinders
  • Distribution valves or pipework damaged or blocked
  • Crew unable to explain how to release the system

Typical root causes

  • Annual or periodic service overdue
  • Corrosion in the CO2 room and pipework
  • Lack of drills on the fixed system

Corrective action (example)

Arrange service by an approved firm; repair alarms, controls and the time delay; replace or refill cylinders; run a drill on the release procedure.

Preventive action (example)

Track service due dates in the certificate tracker; include fixed-system operation in the drill matrix; inspect the CO2 room monthly.

Evidence to attach for close-out

  • Approved service report and certificate
  • Cylinder weighing or level records
  • Drill record covering the fixed system
  • Photos of repaired items

Related

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.