DRAFT, needs technical review. Not for publication. The title is our own wording, not the official Paris MoU text.

PSC deficiency code 07115: Fire dampers and flaps in ventilation trunks

Category Fire safety (SOLAS II-2)
Related certificate Cargo Ship Safety Equipment
Main references SOLAS II-2/9.7 and FSS Code
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Dampers seized open or unable to close fully
  • Missing access for inspection and maintenance
  • Combustible material stored against ventilation trunking
  • Actuator motors disconnected or wired around
  • No records of periodic operation tests

Typical root causes

  • Corrosion and soot binding blades
  • Improvised repairs after cargo hold ventilation work
  • PMS tasks closed without physical verification
  • Inadequate spares for actuator components

Corrective action (example)

Free, lubricate or renew damper assemblies; remove obstructions; operate each damper from local and remote positions; update PMS.

Preventive action (example)

Include damper cycling in fire patrol; stock critical actuator parts where practicable.

Evidence to attach for close-out

  • Before/after photos
  • PMS completion with test notes
  • Inventory of renewed parts
  • Training log entry

Related

  • Codes: 07114, 07116, 07105
  • SIRE 2.0: Chapter 5 (fire safety) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page