Deficiency code: Paris MoU on Port State Control, List of Deficiency Codes including Statutory Certificates (1 July 2026). Page titles are closethecap.com's own wording.
Free close-out tool
Close out this finding
Use our free generator for PSC deficiency code 08101 (General emergency alarm system). Paste your finding text to draft root cause, corrective and preventive actions, and an evidence checklist — no login required.
closethecap.com guidance
Page titles, inspection look-fors, root causes, corrective and preventive actions, references and close-out tips are provided independently by closethecap.com. They are not Paris MoU content and are not endorsed by the Paris MoU.
| Category | LSA / SOLAS III |
| Related certificate | Cargo Ship Safety Equipment |
| Main references | SOLAS III/6.4.2, LSA Code 7.2.1, weekly test SOLAS III/20.6.4 |
| Typical action codes | 17 (rectify before departure), 30 (detainable) if serious |
| Commonly detainable? | Can be, depending on severity (no statistics claimed) |
What PSC officers look for
- General alarm not audible throughout accommodation and machinery spaces
- Public address linked to alarm not functioning
- Alarm buttons or panels defective
- Not audible in normal crew working spaces (LSA 7.2.1)
- No test record for weekly alarm test
Typical root causes
- Speaker corrosion in damp spaces
- Amplifier fault not reported
- Alarm silenced during maintenance and not restored
- New subdivision work without alarm audibility check
Corrective action (example)
Repair amplification and call points; verify audibility on route; test PA integration; document weekly test.
Preventive action (example)
Include audibility walk during abandon-ship drill; stock spare speakers for critical zones.
Evidence to attach for close-out
- Test log signed by master
- Repair work order
- Photos of replaced speakers
- Drill record referencing alarm