DRAFT, needs technical review. Not for publication. The title is our own wording, not the official Paris MoU text.

PSC deficiency code 11101: Lifeboats, including stowage and launching readiness

Category Life-saving appliances (SOLAS III)
Related certificate Cargo Ship Safety Equipment
Main references SOLAS III/31 and LSA Code
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Boat not ready for immediate launching
  • Drain plug missing; hull cracks or water in boat
  • Release gear not maintained or incorrectly rigged
  • Embarkation ladder or painter not ready
  • Maintenance stickers overdue

Typical root causes

  • Weekly inspection ticked without physical check
  • Deferred servicing due to parts delay
  • Confusion between free-fall and davit maintenance rules
  • Crew turnover without boat drill participation

Corrective action (example)

Complete outstanding maintenance; repair hull and release gear; restow equipment per checklist; conduct launching drill to company standard.

Preventive action (example)

Align with authorised service station schedule; cross-check weekly logs with chief officer rounds.

Evidence to attach for close-out

  • Service report
  • Checklist photos
  • Drill log
  • Spares used list

Related

  • Codes: 11112, 11104, 04110
  • SIRE 2.0: Chapter 9 (contingency planning) (chapter reference only)

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page