PSC deficiency code 10126: Records of fire, abandon-ship and steering gear drills

Deficiency code: Paris MoU on Port State Control, List of Deficiency Codes including Statutory Certificates (1 July 2026). Page titles are closethecap.com's own wording.

Free close-out tool

Close out this finding

Use our free generator for PSC deficiency code 10126 (Records of fire, abandon-ship and steering gear drills). Paste your finding text to draft root cause, corrective and preventive actions, and an evidence checklist — no login required.

closethecap.com guidance

Page titles, inspection look-fors, root causes, corrective and preventive actions, references and close-out tips are provided independently by closethecap.com. They are not Paris MoU content and are not endorsed by the Paris MoU.

Category Navigation (SOLAS V) / Emergency drills
Related certificate —
Main references SOLAS III/19 and SOLAS V/26
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Drill log gaps beyond SOLAS intervals
  • Steering gear drill not recorded within required period
  • Entries not signed or missing key details (weather, participants)
  • Combined drill records unclear which requirements were met
  • Electronic logs not backed up or printable

Typical root causes

  • Heavy port workload causing missed drill dates
  • Template log not understood by new master
  • Assumption that muster only satisfies abandon-ship drill
  • Office audit not reviewing drill frequency

Corrective action (example)

Conduct outstanding drills; reconstruct log entries only where factually accurate with master statement; implement clear drill schedule on board.

Preventive action (example)

Office monthly review of drill log extracts; auto-reminder from SMS software.

Evidence to attach for close-out

  • Completed drill logs
  • Attendance lists
  • Photos or checklist from drill
  • Master's corrective note to company

Related

  • Codes: 04109, 04110, 02105
  • SIRE 2.0: Chapter 5 (fire safety) (chapter reference only)

Free close-out tool

Generate your close-out report

Use our free generator for PSC deficiency code 10126 (Records of fire, abandon-ship and steering gear drills). Paste your finding text to draft root cause, corrective and preventive actions, and an evidence checklist — no login required.