PSC deficiency code 04102: Emergency fire pump and sea suction arrangements
| Category | Emergency systems (SOLAS II-2) |
| Related certificate | Cargo Ship Safety Equipment |
| Main references | SOLAS II-2/10.2.1.3 and FSS Code |
| Typical action codes | 17 (rectify before departure), 30 (detainable) if serious |
| Commonly detainable? | Can be, depending on severity (no statistics claimed) |
What PSC officers look for
- Emergency fire pump fails to start or deliver pressure
- Suction valve frozen or sea chest blocked
- Fuel or power supply to pump inadequate
- Emergency switch inaccessible or unmarked
- No recent test with fire main isolated
Typical root causes
- Infrequent testing of emergency pump alone
- Sea chest fouling not addressed in underwater work
- Battery or starter motor defects
- Assumption that main fire pump test covers emergency unit
Corrective action (example)
Restore pump operation; clean suction; repair starter and fuel system; conduct standalone load test and record.
Preventive action (example)
Schedule monthly emergency pump test distinct from main pump; track sea chest maintenance.
Evidence to attach for close-out
- Test log with pressure and duration
- Work order for repairs
- Photos of valve positions
- Spare parts invoice if used
Related
Generate a close-out report for this finding · Download the CAP template
Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.