DRAFT, needs technical review. Not for publication. The title is our own wording, not the official Paris MoU text.

PSC deficiency code 07111: Personal equipment for fire safety (firefighter's outfits, breathing apparatus)

Category Fire safety (SOLAS II-2)
Related certificate Cargo Ship Safety Equipment
Main references SOLAS II-2/10.10 and FSS Code ch. 3
Typical action codes 17 (rectify before departure), 30 (detainable) if serious
Commonly detainable? Can be, depending on severity (no statistics claimed)

What PSC officers look for

  • Breathing-apparatus cylinders not full or overdue for testing
  • Firefighter's outfits incomplete (lamp, axe, lifeline, boots)
  • EEBDs missing, expired or damaged
  • Crew unable to don the apparatus correctly

Typical root causes

  • No regular check of air pressure
  • Equipment taken for drills or maintenance and not returned
  • Training focused on paperwork rather than practice

Corrective action (example)

Refill or replace cylinders; complete outfits; replace EEBDs; run practical donning training.

Preventive action (example)

Weekly BA pressure check in the PMS; equipment checklist at each locker; practical BA drill every month.

Evidence to attach for close-out

  • Pressure check log
  • Hydrostatic test certificates
  • Training record with names
  • Photos of completed outfits

Related

Generate a close-out report for this finding · Download the CAP template


Official code list: Paris MoU, List of Deficiency Codes (1 July 2026). Action codes: Paris MoU, Inspection outcome. Reviewed by: _pending_ · Review date: _pending_ This page is general guidance, not legal, flag or class advice. Always follow the PSC officer's instructions and your flag and class requirements.

Next steps

Generate a close-out report for this finding

Report an error on this page